Abstract
The conventional approach to harvest of the gracilis muscle flap necessitates a medial thigh incision that is often related to several donor site complications. In this report we describe the robotic harvest of the free gracilis muscle flap in order to reduce the morbidity associated with the open incision. Through three ports, the robotic system (Da Vinci Xi, Intuitive Surgical) enables precise dissection of the gracilis muscle, the vascular pedicle, and the obturator nerve; thus, enhancing surgical control, optimizing visualization through magnification, aiding in detailed vascular pedicle dissection and minimizing human error. We believe that the technique of totally robotic harvest of the free gracilis muscle flap, herein introduced, is a feasible and effective approach, and confers specific advantages over traditional harvest technique.