Effect of age on in-hospital outcomes of transvenous lead extraction for infected cardiac implantable electronic device.
Document Type
Article
Publication Date
4-2024
Publication Title
Pacing and clinical electrophysiology : PACE
Abstract
BACKGROUND: The real-world data on the safety profile of transvenous lead extraction (TLE) for infected cardiac implantable electronic devices (CIED) among elderly patients is not well-established. This study aimed to evaluate the hospital outcomes between patients of different age groups who underwent TLE for infected CIED.
METHOD: Using the Nationwide Readmissions Database, our study included patients aged ≥18 years who underwent TLE for infected CIED between 2017 and 2020. We divided the patients into four groups: Group A. Young (<50 >years), Group B. Young intermediate (50-69 years old), Group C. Older intermediate (70-79 years old), and Group D. Octogenarian (≥80 years old). We then analyzed the in-hospital outcome and 30-day readmission between these age groups.
RESULTS: A total of 10,928 patients who were admitted for TLE of infected CIED were included in this study: 982 (9.0%) patients in group A, 4,234 (38.7%) patients in group B, 3,204 (29.3%) patients in group C and 2,508 (23.0%) of patients in group D. Our study demonstrated that the risk of early mortality increased with older age (Group B vs. Group A: OR: 1.92, 95% CI: 1.19-3.09, p < .01; Group C vs. Group A: OR: 2.47, 95% CI: 1.51-4.04, p < .01; Group D vs. Group A: OR: 2.82, 95% CI: 1.69-4.72, p < .01). The risk of non-home discharge also increased in elderly groups (Group B vs. Group A: OR: 1.89; 95% CI: 1.52-2.36; p < .01; Group C vs. Group A: OR: 2.82; 95% CI 2.24-3.56; p < .01; Group D vs. Group A: OR: 4.16; 95% CI: 3.28-5.28; p < .01). There was no significant difference in hospitalization length and 30-day readmission between different age groups. Apart from a higher rate of open heart surgery in group A, the procedural complications were comparable between these age groups.
CONCLUSION: Elderly patients had worse in-hospital outcomes in early mortality and non-home discharge following the TLE for infected CIED. There was no significant difference between elderly and non-elderly groups in prolonged hospital stay and 30-day readmission. Elderly patients did not have a higher risk of procedural complications.
Volume
47
Issue
4
First Page
577
Last Page
582
Recommended Citation
Tan MC, Ang QX, Yeo YH, Thong JY, Tolat A, Scott LR, et al Effect of age on in-hospital outcomes of transvenous lead extraction for infected cardiac implantable electronic device. Pacing Clin Electrophysiol. 2024 Apr;47(4):577-582. doi: 10.1111/pace.14939. PMID: 38319639.
DOI
10.1111/pace.14939
ISSN
1540-8159
PubMed ID
38319639